Enter the flow rate and the inside diameter of a pipe to find how fast the water is moving.

Example: A customer complains of water hammer. Check whether 8 gallons a minute through a half inch line is simply too fast.

Your numbers

Use the inside diameter. A nominal ¾ inch type L copper pipe is about 0.785 inches inside.

gpm
in
  • Velocity0
  • Pipe opening0
  • Flow per hour0

How the velocity is worked out

Velocity is the flow divided by the area of the pipe opening. With flow in gallons per minute and diameter in inches, that simplifies to one constant.

Feet per second = 0.4085 × gallons per minute ÷ diameter²

A worked example

Eight gallons a minute through a pipe 0.785 inches inside moves at 5.3 feet per second.

Good to know

  • Fast water is noisy, causes water hammer and wears out copper, especially at elbows. Commonly cited limits are about 8 feet per second for cold water and 5 for hot.
  • Halving the diameter makes the water move four times as fast for the same flow.
  • If the velocity is too high, the fix is a larger pipe or less flow through that run.
  • This shows speed only. Pressure loss also depends on length, fittings and pipe material.

Common questions

How do I find the flow rate?

Time how long a tap takes to fill a bucket of known size. A 5 gallon bucket filled in 30 seconds is 10 gallons per minute.

How we know this calculator is right

Before this calculator went on the site, 5 answers were worked out separately from its code, by hand or straight from the formula above. Each time this page loads, your own browser runs the calculator on those same numbers and compares. Turn on JavaScript to see the comparison.

See every check
Numbers usedResultWorked out separatelyThis calculator

What this proves: the calculator does the arithmetic of the formula shown, correctly. What it cannot prove: your measurements, or figures such as coverage per bag, waste and spacing, which are typical starting values you can change. Go by the product label and your local code.

Used by: plumbers and pipefitters, irrigation installers.